Display unit selecting mode
(When Unit spec. in Model Indication is w/o "M")
Unit can be selected from that of Instantaneous flow and integrated
flow. The unit is changed by pressing
▲
button.
It will be set up if the button is pressed.
If the button is
pressed instead of
the button, it will
change to「F_3」
.
14 15
Display
Instantaneousd flow
/min
CFM
U_1
U_2
Intrgrated flow
,m
3
,m
3
×
10
3
ft
3
,
ft
3
×
10
3
,
ft
3
×
10
6
2. Display selecting mode
Select the display from instantaneous flow or
integrated flow. Press
▲
button to select desired flow, then
press button.
「d_1」means instantaneous flow,「d_2」integrated flow.
3. Display unit selecting mode
Display unit can be selected when the unit spec. of model
Indication is No Symbol. -M means the unit is fixed to SI unit. It
does not go into Display unit selecting mode. See "Display unit
selecting mode" below for details.
Function Setting (continue)
6. Key lock mode
Prevents wrong operation such as unintentional change of set
value.
LOCK
・Press button, and the display changes from
「F_5」to「unL」.
・Set the display as「Loc」by
▲
button
・Mode changed to「F_6」by pressing button.
(「F_7」when selecting「oU1_2」during「F_3」)
・Setting completed by pressing button.
RELEASE
・Press button longer than 3 sec. at the normal
mode to display「F_5」, then press button.
・Press
▲
button to display 「unL」.
・Setting completed by pressing button.
4. Output specification selecting mode
Set OUT1 output specifications.
Press
▲
button to select OUT1 output spec., then press
button.「oU1_0」indicates instantaneous switch output,
「oU1_1」integrated switch output and「oU1_2」integrated
pulse output.
See "OUT1 output specifications".
Input the set value after selecting OUT1 output specifications.
See "7. Flow rate setting mode" for details.
Flow setting not required when selecting integrated pulse
output「oU1_2」.
5. Output method selecting mode
Set OUT1 output mode. Reverse output and
non-reverse output mode are available for output.
*Press
▲
button to select the mode from reverse output or
non-reverse output. And press button is to set.
「oU1_n」indicates reverse output mode,「oU1_P」is
non-reverse output mode.
Pressing
button instead of
button switches to「F_5」.